巡檢常見問題及解決方案(一)-創(chuàng)新互聯(lián)

1.端口下出現(xiàn)CRC錯包統(tǒng)計

創(chuàng)新互聯(lián)建站是專業(yè)的大冶網(wǎng)站建設(shè)公司,大冶接單;提供網(wǎng)站建設(shè)、成都網(wǎng)站設(shè)計,網(wǎng)頁設(shè)計,網(wǎng)站設(shè)計,建網(wǎng)站,PHP網(wǎng)站建設(shè)等專業(yè)做網(wǎng)站服務(wù);采用PHP框架,可快速的進行大冶網(wǎng)站開發(fā)網(wǎng)頁制作和功能擴展;專業(yè)做搜索引擎喜愛的網(wǎng)站,專業(yè)的做網(wǎng)站團隊,希望更多企業(yè)前來合作!

例如:

XGigabitEthernet0/0/1 current state : UP

Line protocol current state : UP

Description:

Switch Port, Link-type : access(negotiated),

PVID :   1, TPID : 8100(Hex), The Maximum Frame Length is 9012

IP Sending Frames' Format is PKTFMT_ETHNT_2, Hardware address is 4cf9-5d39-efa0

Current system time: 2017-12-08 14:10:22

Port Mode: COMMON FIBER, Transceiver: UNKNOWN_SFP

Speed : 10000, Loopback: NONE

Duplex: FULL,  Negotiation: DISABLE

Mdi  : -,     Flow-control: DISABLE

Last 300 seconds input rate 1981032 bits/sec, 789 packets/sec

Last 300 seconds output rate 13763216 bits/sec, 1234 packets/sec

Input peak rate 3900736744 bits/sec, Record time: 2016-12-20 15:58:51

Output peak rate 1579418400 bits/sec, Record time: 2017-06-11 07:56:25

Input: 8074383226 packets, 3301841306523 bytes

 Unicast:                8072437737, Multicast:                    1008305

 Broadcast:                       1, Jumbo:                              0

 Discard:                         0, Pause:                         937183

 Frames:                          0

 Total Error:                     828399

 CRC:                             838399, Giants:                             0

 Runts:                           0, DropEvents:                         0

 Alignments:                      0, Symbols:                            0

 Ignoreds:                        0

Output: 11492763448 packets, 15396671657189 bytes

 Unicast:               11475385794, Multicast:                   16770945

 Broadcast:                  606709, Jumbo:                              0

 Discard:                        12, Pause:                              0

 Total Error:                     0

 Collisions:                      0, Late Collisions:                    0

 Deferreds:                       0

   Input bandwidth utilization threshold : 80.00%

   Output bandwidth utilization threshold: 80.00%

   Input bandwidth utilization : 0.02%

   Output bandwidth utilization : 0.14%

發(fā)現(xiàn)接口的Input方向存在CRC的錯包則表示曾經(jīng)或者現(xiàn)在存在上游發(fā)出的包里面存在錯包現(xiàn)象

需要排查

解決方案:檢查上游設(shè)備狀態(tài),是否存在丟包,光功率不正常等現(xiàn)象,

如果之前就出現(xiàn)了,但是存在數(shù)據(jù)沒有清除需要觀察包的數(shù)量是否增加,如果沒有增加可以將接口下清除統(tǒng)計信息,避免不必要的報錯,通過命令 reset count interface XG 0/0/1 清除接口下所有的數(shù)據(jù)統(tǒng)計信息。

2.查看光模塊的參數(shù)信息,存在異常

[G14_WR_NE20E_A-diagnose]display optical-module extend information slot 17 card 14

===============================================================================

Transceiver Digital Diagnostic Monitoring (DDM), Internally Calibrated

=============|=================================================================

Card14-Port0 +              Value HighAlarm HighWarn LowWarn LowAlarm Status

-------------|-----------------------------------------------------------------

Temperature(C)              34.527 80.000  70.000   0.000 -10.000 Normal

Supply Voltage(V)            3.307  3.630   3.465   3.135   2.970 Normal

Tx Bias(mA)                  5.340 20.000  15.000   1.000   1.000 Normal

Tx Power(avg dBm)           -2.281  0.999  -1.000  -7.300  -9.299 Normal

Rx Power(avg dBm)          -40.000  0.999  -1.000  -9.901 -11.897 Abnormal

=============|=================================================================

display transceiver interface gigabitethernet 0/0/1 verbose

接受的光功率過低,可能為光纖沒有接好,或者對端沒有發(fā)光

3.電源顯示不正常

display power

------------------------------------------------------------

Slot   PowerID Online  Mode  State     Power(W)

------------------------------------------------------------

1      PWR1    Present AC    NotSupply 150.00   

1      PWR2    Present AC    Supply    150.00

2      PWR1    Present AC    NotSupply 150.00

2      PWR2    Present AC    Supply    150.00

AC為交流電源

DC為直流電源

可能原因:

客戶就是單電源,并沒有第二塊電源模塊

有第二塊電源,但是沒有加電

確實電源掉電

4.運行的配置文件與保存的配置文件不一致

display configuration changes

5.SNMP協(xié)議版本檢查

display snmp-agent sys-info version

  SNMP version running in the system:

          SNMPv2c SNMPv3

出現(xiàn)配置時同時兼容多個SNMP的版本,沒有影響

6.根據(jù)現(xiàn)網(wǎng)中報的速率判斷如果操作是否會影響業(yè)務(wù)

display interface GigabitEthernet2/0/12

Last 300 seconds input rate 448792 bits/sec, 62 packets/sec

Last 300 seconds output rate 506664 bits/sec, 71 packets/sec

多采幾次將input和output的包速率加起來判斷是否有大量的業(yè)務(wù)運行

7.出現(xiàn)MAC地址飄移

display trapbuffer

#Feb 8 2017 18:37:18+08:00 C05_NAS_S5720_CSS L2IFPPI/4/MFLPVLANALARM:OID 1.3.6.1.4.1.2011.5.25.160.3.7 MAC move detected, VLANID = 3, MacAddress = 244c-0733-3205, Original-Port = Eth-Trunk100, Flapping port = XGE1/0/1. Please check the network accessed to flapping port.

可能原因:

客戶端的移動---此時會在日志中出現(xiàn)簡單的一條MAC飄移,沒有影響

但是如果出現(xiàn)大量的MAC漂移日志,顯示同一mac飄移,可能存在二層的環(huán)路,或者遭受***,檢查stp的狀態(tài),MAC飄移表

display mac-address flapping record

------------------------------------------------------------------------------
Move-Time            VLAN MAC-Address  Original-Port Move-Ports  MoveNum
-------------------------------------------------------------------------------
S:2011-08-31 17:22:36 300 0000-0000-0007 Eth-Trunk1  Eth-Trunk2  81
E:2011-08-31 17:22:44
-------------------------------------------------------------------------------

可以通過配置MAC地址的同優(yōu)先級不能覆蓋,靜態(tài)綁定,允許接入的大MAC數(shù)量

8. 單板工作不正常

display device

CE12808's Device status:

--------------------------------------------------------------------------------

Slot Card  Type                    Online  Power Register    Alarm    Primary

--------------------------------------------------------------------------------

1    -     CE-L48XS-EC             Present On   Registered  Normal   NA

3    -     CE-L48GS-EA             Present On   Registered  Normal   NA

5    -     CE-L48GT-EA             Present On   Registered  Normal   NA

9    -     CE-MPUA                 Present On   Registered  Normal   Master

10   -     CE-MPUA                 Present On   Registered  Normal   Slave

11   -     CE-CMUA                 Present On   Registered  Normal   Master

12   -     CE-CMUA                 Present On   Registered  Normal   Slave

13   -     CE-SFU08A               Present On   Registered  Normal   NA

14   -     CE-SFU08A               Present On   Registered  Normal   NA

15   -     CE-SFU08A               Present On   Registered  Normal   NA

16   -     CE-SFU08A               Present On   Registered  Normal   NA

17   -     CE-SFU08A               Present On   Registered  Normal   NA

18   -     -                       Present Off  Unregistered -        NA

PWR1 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR2 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR3 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR4 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR5 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR6 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR7 -     PAC-2700WA              Present On   Registered  Normal   NA

PWR8 -     PAC-2700WA              Present On   Registered  Normal   NA

FAN1 -     FAN-12C                 Present On   Registered  Normal   NA

FAN2 -     FAN-12C                 Present On   Registered  Normal   NA

FAN3 -     FAN-12C                 Present On   Registered  Normal   NA

FAN4 -     FAN-12C                 Present On   Registered  Normal   NA

FAN5 -     FAN-12C                 Present On   Registered  Normal   NA

FAN6 -     FAN-12C                 Present On   Registered  Normal   NA

FAN7 -     FAN-12C                 Present On   Registered  Normal   NA

FAN8 -     FAN-12C                 Present On   Registered  Normal   NA

FAN9 -     FAN-12C                 Present On   Registered  Normal   NA

FAN10 -     FAN-12C                 Present On   Registered  Normal   NA

FAN11 -     FAN-12C                 Present On   Registered  Normal   NA

FAN12 -     FAN-12C                 Present On   Registered  Normal   NA

FAN13 -     FAN-12C                 Present On   Registered  Normal   NA

--------------------------------------------------------------------------------

display switchover state

  Switchover State : Ready

  Switchover Policy : Board Switchover

  MainBoard        : 9

  SlaveBoard       : 10

建議查看單板是否插緊或者更換單板,可能是沒有插板卡

另外有需要云服務(wù)器可以了解下創(chuàng)新互聯(lián)scvps.cn,海內(nèi)外云服務(wù)器15元起步,三天無理由+7*72小時售后在線,公司持有idc許可證,提供“云服務(wù)器、裸金屬服務(wù)器、高防服務(wù)器、香港服務(wù)器、美國服務(wù)器、虛擬主機、免備案服務(wù)器”等云主機租用服務(wù)以及企業(yè)上云的綜合解決方案,具有“安全穩(wěn)定、簡單易用、服務(wù)可用性高、性價比高”等特點與優(yōu)勢,專為企業(yè)上云打造定制,能夠滿足用戶豐富、多元化的應(yīng)用場景需求。